Version 3.1.7
Section titled “Version 3.1.7”🔧Fix: When adding monitors with a large number of instances, Monsta displays a timeout message.
Version 3.1.6
Section titled “Version 3.1.6”🔧Fix: In some cases memory leaks and failures occurred in the execution of some monitors.
Version 3.1.5
Section titled “Version 3.1.5”✨New: Retry count was increased to 120.
✨New: “Search Device” filter also searches by IP address.
✨New: String Type accepts hexadecimal values.
✨New: String Type accepts text.
✨New: WMI search accepts other namespaces.
✨New: Function return() in a script can force the state of a metric in a monitor.
✨New: Sound alert for status changes.
✨New: Ability to publish a link to a monitor without requiring login.
✨New: Template Unbound - DNS Server.
✨New: Template Intelbras - Switches.
✨New: Template Microsoft - Windows (Inventory).
✨New: Monitors “Services Running”, “Motherboard Status”, “Physical Memory Status”, “Processor Status” and “Power Supply Status” for the Microsoft - Windows template.
✨New: Monitors “Processes”, “Load (Load Average)” and “MAC Address” for the Linux template.
✨New: Monitor “MAC Address” for the templates Generic, Linux, Ubiquiti - AirOS 5.6 and Ubiquiti - Airmax AC.
🔧Fix: State display filter could omit some devices from the list.
🔧Fix: ICMP packet size in the uptime check was ignored.
🔧Fix: Return type was not handled in Monsta templates.
🔧Fix: Selecting a date range in a string-type monitor did not work.
🔧Fix: The uptime history did not show more than 4 months of data.
🔧Fix: Monsta’s init script might not start the application after a forced stop.
🔧Fix: Sometimes SMS and email credits were shown incorrectly.
🔧Fix: In some cases, the number of devices per state was shown incorrectly.
🔧Fix: Probable fix for sending monitor alerts even with the device **.
🔧Fix: Monitor database would lock up when changing the server’s host name.
🔧Fix: Disabled magnitude unit handling when editing a monitor.
🔧Fix: “Connected Clients” monitor of the Airmax AC and Ubiquiti - AirOS 5.6 templates did not display information.
🔧Fix: “Interface Errors” monitor of the Ubiquiti - Airmax AC template did not display the network interfaces.
🔧Fix: “Input Frequency” monitor of the Nobreak - Generic template had the maximum limit calculation wrong.
Version 3.0.13
Section titled “Version 3.0.13”✨New: New templates available.
Version 3.0.11
Section titled “Version 3.0.11”✨New: Users and restrictions for devices.
✨New: Device groups.
✨New: View by device groups.
✨New: Provided program to reset the admin user’s password to the default at /opt/monsta/bin/resetadmin.
🔧Fix: The Uptime monitor does not allow viewing history older than 6 days.
🔧Fix: The cloud connection icon sometimes incorrectly appears as critical state.
🔧Fix: Cloud connection history is not recorded in the Timeline.
🔧Fix: In an existing monitor, cloning metrics whose description is a number causes the “Ok” button to not work.
🔧Fix: Process supervision mechanism does not properly control the automatic update process.
🔧Fix: In an existing monitor, a cloned metric copies the original’s maximum value.
🔧Fix: The uptime monitor does not display information about the Up and Down states.
🔧Fix: Probable fix for monitor database corruption when Monsta is terminated.
🔧Fix: When a metric is deleted from a monitor, it does not appear on the graph but continues to be monitored.